We always send flowinfo to the kernel. If flowlabel/tclass
was set first to non-inherit value and then reset to
inherit we do not clear flowlabel/tclass part in flowinfo,
send it to kernel and can get from the kernel back.
Even if we check for IP6_TNL_F_USE_ORIG_TCLASS and
IP6_TNL_F_USE_ORIG_FLOWLABEL when printing options
sending invalid flowlabel/tclass to the kernel seems
bad idea.
Note that ip6tnl always clean corresponding flowinfo
parts on inherit.
Signed-off-by: Serhey Popovych <serhe.popovych@gmail.com>
Since rtnl_talk() never returns with answer buffer allocated
on error we do not need to release it manually. After this
initializing answer with NULL before rtnl_talk() is useless.
Signed-off-by: Serhey Popovych <serhe.popovych@gmail.com>
It is added with
commit a7ed1520ee ("ip/tunnel: introduce tnl_parse_key()")
to avoid code duplication in ip6?tunnel.c.
Reuse it for gre/gre6 and vti/vti6 tunnel rtnl
configuration interface with the same purpose
it is used in tunnel ioctl interface in ip6?tunnel.c.
While there change type of key variables from
unsigned integer to __be32 to reflect nature of the
value they store and place error message in
tnl_parse_key() on a single line to make single
call to fprintf().
Signed-off-by: Serhey Popovych <serhe.popovych@gmail.com>
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
Manual page ip-link(8) states that both local and remote accept
IPADDR not PREFIX. Use get_addr() instead of get_prefix() to
parse local/remote endpoint address correctly.
Force corresponding address family instead of using preferred_family
to catch weired cases as shown below.
Before this patch it is possible to create tunnel with commands:
ip li add dev ip6gre2 type ip6gre local fe80::1/64 remote fe80::2/64
ip -4 li add dev ip6gre2 type ip6gre local 10.0.0.1/24 remote 10.0.0.2/24
Signed-off-by: Serhey Popovych <serhe.popovych@gmail.com>
Looks like a typo: get_u8() returns 0 on success and -1 on error, so the
error checking here was ineffective.
Fixes: a11b7b71a6 ("link_gre6: really support encaplimit option")
Signed-off-by: Phil Sutter <phil@nwl.cc>
This is an update for 460c03f3f3 ("iplink: double the buffer size also in
iplink_get()"). After update, we will not need to double the buffer size
every time when VFs number increased.
With call like rtnl_talk(&rth, &req.n, NULL, 0), we can simply remove the
length parameter.
With call like rtnl_talk(&rth, nlh, nlh, sizeof(req), I add a new variable
answer to avoid overwrite data in nlh, because it may has more info after
nlh. also this will avoid nlh buffer not enough issue.
We need to free answer after using.
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
Signed-off-by: Phil Sutter <phil@nwl.cc>
Print the value analogous to flowlabel. While being at it, also break
the overlong lines to not exceed 80 characters boundary.
Signed-off-by: Phil Sutter <phil@nwl.cc>
When trying to change tclass or flowlabel of a GREv6 tunnel which has
the respective value set already, the code accidentally bitwise OR'ed
the old and the new value, leading to unexpected results. Fix this by
clearing the relevant bits of flowinfo variable prior to assigning the
new value.
Fixes: af89576d7a ("iproute2: GRE over IPv6 tunnel support.")
Signed-off-by: Phil Sutter <phil@nwl.cc>
This option is documented in gre6 help, but was not supported.
Fixes: af89576d7a ("iproute2: GRE over IPv6 tunnel support.")
Signed-off-by: Nicolas Dichtel <nicolas.dichtel@6wind.com>
This attribute allows the administrator to adjust the packet marking
attribute of tunnels that support policy based routing.
Signed-off-by: Craig Gallek <kraig@google.com>
Take help function in iplink_bridge.c as an example and make other link
types' help functions similar:
* Use a single fprintf() call (if possible).
* Don't state a full command line, just "... type OPTIONS".
* Put every option in it's own line, align options by column.
* List mandatory options first.
link_veth.c is intentionally left untouched because it's 'peer' option
eats all kinds of generic link options and the help text points this out
without duplicating all the options there again.
Signed-off-by: Phil Sutter <phil@nwl.cc>
This big patch was compiled by vimgrepping for memset calls and changing
to C99 initializer if applicable. One notable exception is the
initialization of union bpf_attr in tc/tc_bpf.c: changing it would break
for older gcc versions (at least <=3.4.6).
Calls to memset for struct rtattr pointer fields for parse_rtattr*()
were just dropped since they are not needed.
The changes here allowed the compiler to discover some unused variables,
so get rid of them, too.
Signed-off-by: Phil Sutter <phil@nwl.cc>
Acked-by: David Ahern <dsa@cumulusnetworks.com>
There are only three users which require it to be reentrant, the rest is
fine without. Instead, provide a reentrant format_host_r() for users
which need it.
Signed-off-by: Phil Sutter <phil@nwl.cc>
There have been several instances where response from kernel
has overrun the stack buffer from the caller. Avoid future problems
by passing a size argument.
Also drop the unused peer and group arguments to rtnl_talk.
Allow to print particular link type usage by:
ip link help [TYPE]
Currently to print usage for some link type it is needed
to use the following way:
ip link { add | del | set } type TYPE help
Signed-off-by: Vadim Kochan <vadim4j@gmail.com>
When we create a tunnel on top of a link and the link specified
in cmdline doesn't exist, an error message should be shown.
Cc: Stephen Hemminger <stephen@networkplumber.org>
Signed-off-by: Cong Wang <xiyou.wangcong@gmail.com>